669
set event-parameters
This command specifies the notifications of an event other than the notifications specified in the "set event-
notification" command.
■ Syntax
■ Parameter
■ Example(s)
set event-parameters [-blink-panel-led {enable | disable} ] [-redundant-copy-led {enable | disable}]
-blink-panel-led
Optional. This parameter specifies whether the Panel FAULT LED will blink when the system is
in "warning" status.
enable The Panel FAULT LED will blink.
disable The Panel FAULT LED will not blink.
-redundant-copy-led
Optional. This parameter specifies whether the FAULT LED will turn on after the redundant
copy is complete.
enable The Fault LED will turn on after the redundant copy is complete.
disable The Fault LED will not turn on after the redundant copy is complete.
The following example sets the event parameters:
CLI> set event-parameters -blink-panel-led enable -redundant-copy-led enable