Chapter 3 Configuration Settings and Display
3.3 RAID Group Management > create eco-schedule
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED P2X0-1030-09ENZ0
133
■ Example(s)
-event-from This parameter specifies that the ECO schedule will apply to a specific starting time. The format
is "hhmm". "hh" is the starting hour (00 – 23) and "mm" is the starting minute (00 or 30).
A disk motor will power ON at the time specified by this parameter.
-event-to This parameter specifies that the ECO schedule will end at a specific time. The format is
"hhmm". "hh" is the ending hour (00 – 23) and "mm" is the ending minute (00 or 30).
The following example creates an ECO schedule. The ECO schedule name is "SC001". The ECO schedule will
apply every day from 06:00 to 18:00:
CLI> create eco-schedule -name SC001 -event-type every-day -event-from 0600 -event-to 1800