Chapter 3 Configuration Settings and Display
3.5 Host Interface Management > show host-lu-qos-performance
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED P2X0-1030-09ENZ0
355
The following example displays the performance measurement information when a host interface port with
the host affinity mode enabled and a host (the port type is iSCSI and the host IP address is not set) are set:
CLI> show host-lu-qos-performance -port 000 -host-number 0
CM#0 CA#0 Port#0 Port Performance Information
Port Type ISCSI
Host Affinity Enable
Performance Monitoring ON
Monitoring Start Time 2012-04-11 12:00:00
Monitoring Stop Time 2012-04-11 12:05:00
Host Performance Information
Host No. 0
Host Name HOST#0
iSCSI Name iqn.1991-05.com.microsoft
IP Address 192.168.43.151
IOPS Throughput(MB/s) Delay Time(ms)
Ave Min Max Ave Min Max Total Ave
Host Total 111000 110 222000 20 10 30 1000 10
IOPS Throughput(MB/s) Delay Time(ms)
LUN Ave Min Max Ave Min Max Total Ave
1 20 10 100 2 1 3 20 10
1021 60 11 30 2 1 2 120 10
Host Performance Information
Host No. 0
Host Name HOST#0
iSCSI Name iqn.1991-05.com.microsoft
IP Address 192.168.43.152
IOPS Throughput(MB/s) Delay Time(ms)
Ave Min Max Ave Min Max Total Ave
Host Total 111000 110 222000 20 10 30 1000 10
IOPS Throughput(MB/s) Delay Time(ms)
LUN Ave Min Max Ave Min Max Total Ave
1 20 10 100 2 1 3 20 10
1021 60 11 30 2 1 2 120 10
The following example displays the performance measurement information when performance
measurements are not performed and a host interface port is set:
CLI> show host-lu-qos-performance -port 000
CM#0 CA#0 Port#0 Port Performance Information
Port Type ISCSI
Host Affinity Enable
Performance Monitoring OFF

Table of Contents