EasyManua.ls Logo

Fujitsu Eternus DX90 S2 - Page 40

Fujitsu Eternus DX90 S2
756 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Status Display
2.1 Storage System Status > show enclosure-status
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED P2X0-1030-09ENZ0
40
The following example shows the information that is displayed when all of the enclosures are specified for
the ETERNUS DX8700 S2:
CLI> show enclosure-status -type all
Controller Enclosure Information
Location Status Error Code Temperature
Intake Temp Normal 0x0000 25 (C)
Exhaust Temp Normal 0x0000 -
Controller Enclosure Status
Controller Module Status/Status Code
CM#0 [Normal / 0xE001]
CM#1 [Normal / 0xE001]
CM#2 [Normal / 0xE001]
CM#3 [Normal / 0xE001]
CM#4 [Normal / 0xE001]
CM#5 [Normal / 0xE001]
CM#6 [Normal / 0xE001]
CM#7 [Normal / 0xE001]
Front End Router Status/Status Code
FRT#0 [Normal / 0xE001]
FRT#1 [Normal / 0xE001]
FRT#2 [Normal / 0xE001]
FRT#3 [Normal / 0xE001]
Back End Router Status/Status Code
BRT#0 [Normal / 0xE001]
BRT#1 [Normal / 0xE001]
BRT#2 [Normal / 0xE001]
BRT#3 [Normal / 0xE001]
BRT#4 [Normal / 0xE001]
BRT#5 [Normal / 0xE001]
BRT#6 [Normal / 0xE001]
BRT#7 [Normal / 0xE001]
Service Controller Status/Status Code
SVC#0 [Normal / 0xE001]
SVC#1 [Normal / 0xE001]
FAN Unit Status/Status Code
FANU#0 [Normal / 0xE001]
FANU#1 [Normal / 0xE001]
FANU#2 [Normal / 0xE001]
FANU#3 [Normal / 0xE001]
Operation Panel Status/Status Code
OPNL [Normal / 0xE001]
Power Supply Unit Status/Status Code
PSU#0 [Normal / 0xE001]
PSU#1 [Normal / 0xE001]
PSU#2 [Normal / 0xE001]
PSU#3 [Normal / 0xE001]
PSU#4 [Normal / 0xE001]
PSU#5 [Normal / 0xE001]
Drive Enclosure #0 Information
Location Status Error Code Sensor 1 / Sensor 2
Intake Temp Normal 0x0000 25 (C) / 25 (C)
Exhaust Temp Normal 0x0000 -
Drive Enclosure #0 Status
I/O Module Status/Status Code
IOM#0 [Normal / 0xE001]
IOM#1 [Normal / 0xE001]
Power Supply Unit Status/Status Code
PSU#0 [Normal / 0xE001]
PSU#1 [Normal / 0xE001]
Disk Status
DE#00-Disk#0 [Available ] DE#00-Disk#1 [Available ]
DE#00-Disk#2 [Available ] DE#00-Disk#3 [Rebuild/Copyback ]
DE#00-Disk#4 [Rebuild/Copyback ] DE#00-Disk#5 [Available ]
DE#00-Disk#6 [Available ] DE#00-Disk#7 [Available(Predictive Failure)]
DE#00-Disk#8 [Available ] DE#00-Disk#9 [Available ]
DE#00-Disk#10 [Available ] DE#00-Disk#11 [Broken ]
DE#00-Disk#12 [Available ] DE#00-Disk#13 [Available ]
DE#00-Disk#14 [Available ] DE#00-Disk#15 [Available ]
DE#00-Disk#16 [Available ] DE#00-Disk#17 [Available ]
DE#00-Disk#18 [Available ] DE#00-Disk#19 [Available ]
DE#00-Disk#20 [Available ] DE#00-Disk#21 [Available ]
DE#00-Disk#22 [Available ] DE#00-Disk#23 [Available ]

Table of Contents

Other manuals for Fujitsu Eternus DX90 S2

Related product manuals