Chapter 4 Function/System Settings and Display
4.3 Network Management > create snmp-view
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED P2X0-1030-09ENZ0
477
Example(s)
-exclude-subtree
Optional. This parameter specifies the "exclude" subtree type. A value between 1 and 10 can
be specified for the subtree number. Two or more subtree numbers can be specified by using
"," or "-".
If this parameter and the "-include-subtree" parameter are omitted, "include" is used as the
default for subtree.
The following example creates the MIB view named "1.3". It includes one sub-tree named "1.3.6.1.2.1" in the
MIB view.
CLI> create snmp-view -view xview4 -subtree1 1.3.6.1.2.1 -include-subtree 1
The following example is specified without the "-subtree2" parameter when "-subtree1", "-subtree3", "-
include-subtree1", and "-exclude-subtree3" are specified:
CLI> create snmp-view -view xview5 -subtree1 1.3.6.1.2.1 -subtree3 1.3.6.1.2.2 -include-subtree 1 -exclude-
subtree 3