Chapter 5 Information Settings and Display
5.3 Maintenance > export panic-dump
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED P2X0-1030-09ENZ0
642
-filename This parameter specifies the name of the panic dump file to be stored on the FTP server. When
panic dump files are divided and stored, the sequential number and the extension (.dmp) are
automatically added to the specified filename. If the same filename already exists, it is
overwritten.
Example: Panic dump is divided into three files if needed.
-filename /tmp/dump
"/tmp/dump01.log", "/tmp/dump02.log", and "/tmp/dump03.log" are created automatically.
The following conversion specifications, which begin with a percent character, are replaced by
their corresponding values during file creation.
If other conversion strings are specified, this command terminates abnormally with an error
message.
%s Serial number of the system
Example:
/tmp/%s-log.bin -> /tmp/123456789012-log.bin
%d Current date
Example:
/tmp/%d-log.bin -> /tmp/20080819-log.bin
%t Current time
Example:
/tmp/%t-log.bin -> /tmp/144855-log.bin
%%Percent character
Example:
/tmp/log%%.bin -> /tmp/log%.bin
-dump-number
One or more panic dumps can be stored in the system. They can be displayed by using the
"show panic-dump" command. This parameter specifies the panic dump number to be
exported.
-divide Optional. This parameter specifies the file size when the dump is divided into multiple files. If
this parameter is omitted, the default value ("not divided") is applied. When "no" is specified,
the log filename is not changed by the system. Otherwise, an ordered numbering system is
used.
no Not divided.
4mb Approximately 4MB (4,372,950 bytes)
1mb Approximately 1MB (1,457,650 bytes)
640kb 640KB (655,360 bytes)
-indicator Optional. This parameter specifies whether the progress indicator is displayed. If omitted, this
function is enabled.
enable Progress indicator is displayed.
disable Progress indicator is not displayed.