Chapter 3 Configuration Settings and Display
3.1 Thin Provisioning Pool Management > expand thin-pro-pool
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED P2X0-1030-09ENZ0
84
Example(s)
For the ETERNUS DX410 S2/DX440 S2 and ETERNUS DX8100 S2:
cm0cpu0 CM#0 CPU#0
cm0cpu1 Controller module#0 CPU#1
cm1cpu0 Controller module#1 CPU#0
cm1cpu1 Controller module#1 CPU#1
auto Automatically (default)
For the ETERNUS DX8700 S2:
cm0cpu0 Controller module#0 CPU#0
cm0cpu1 Controller module#0 CPU#1
cm1cpu0 Controller module#1 CPU#0
cm1cpu1 Controller module#1 CPU#1
cm2cpu0 Controller module#2 CPU#0
cm2cpu1 Controller module#2 CPU#1
cm3cpu0 Controller module#3 CPU#0
cm3cpu1 Controller module#3 CPU#1
cm4cpu0 Controller module#4 CPU#0
cm4cpu1 Controller module#4 CPU#1
cm5cpu0 Controller module#5 CPU#0
cm5cpu1 Controller module#5 CPU#1
cm6cpu0 Controller module#6 CPU#0
cm6cpu1 Controller module#6 CPU#1
cm7cpu0 Controller module#7 CPU#0
cm7cpu1 Controller module#7 CPU#1
auto Automatically (default)
The following example expands Thin provisioning pool#01 by adding a RAID group (disks 001 to 004/CM#0-
CPU#0):
CLI> expand thin-pro-pool -pool-number 01 -disks 001-004 -assigned-cm cm0cpu0
The following example expands Thin provisioning pool#02 by adding a RAID group (capacity 900GB/CM#1-
CPU#1):
CLI> expand thin-pro-pool -pool-number 02 -capacity 900G -assigned-cm cm1cpu1