EasyManua.ls Logo

Fujitsu Eternus DX90 - Page 119

Fujitsu Eternus DX90
239 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Cable Connection
> 6.6 MiniSAS Cable Connection (For Drive Enclosures)
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
119
Copyright 2010 FUJITSU LIMITED
P3AM-3042-06ENZ0
Procedure
1 Connect the controller enclosure to the drive enclosure with the miniSAS cable.
1-1 Connect the SAS (OUT) port at controller 0 (CM#0) of controller enclosure, to the SAS
(IN) port at expander 0 (EXP#0) of the drive enclosure 1 with the miniSAS cable.
(1) Connect the plug to be connected to SAS (OUT) port, to the SAS (OUT) port of the
controller 0 (CM#0).
Remove the port cover from the SAS (OUT) port before inserting the plug.
(2) Connect the plug to be connected to SAS (IN) port, to the SAS (IN) port of the
expander 0 (EXP#0).
1-2 For dual controller model, connect the SAS (OUT) port at controller 1 (CM#1) of
controller enclosure, to the SAS (IN) port at expander 1 (EXP#1) of the drive enclosure
1 with the miniSAS cable.
Connect the miniSAS cable in the same way as Step 1-1
.
Controller
enclosure
Drive
enclosure 1