EasyManua.ls Logo

Fujitsu GENERAL ASHG24KMTA - Safety Devices

Fujitsu GENERAL ASHG24KMTA
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11. Safety devices
Type of
protection
Protection form
Model
AOHG18KMTA AOHG24KMTA
Circuit
protection
Current fuse (PCB*)
250 V, 25 A
250 V 5 A
250 V, 3.15 A
Fan motor
protection
Thermal protection program
Activate
100±15°C
Fan motor stop
Reset
95±10°C
Fan motor restart
Compressor
protection
Thermal protection program
(Discharge temp.)
Activate
110°C
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY mode)
Activate
-20 °C
Compressor stop
-15 °C
Compressor stop
Reset
-15 °C
Compressor restart
-10 °C
Compressor restart
- 54 -
11. Safety devices
OUTDOOR UNIT
AOHG18, 24KMTA
OUTDOOR UNIT
AOHG18, 24KMTA

Related product manuals