CHAPTER 10 Expansion File Unit Type-2
IMPORTANT
Adding an optional redundant power supply unit allows hot-swapping of the power supply units.
Power supply units installed on the Expansion File Unit Type-2 are hot-swappable. To enable hot-swapping, use
the tools (machine administration) contained in the "Enhanced Support Facility" to perform hot-swapping. For
details on how to swap power supply units, refer to the "Machine Administration Instructions" included with the
"Enhanced Support Facility".
10.5.2 Hard disk drives
CAUTION
Data Destruction
Data may be lost if hot-swapping of hard disk drives is not performed correctly.
Contact the service engineer if a hard disk drive must be hot-swapped.
IMPORTANT
To utilize the hot-swapping functions of the hard disk drive, use the option software (SynfinityDISK) to
perform mirroring.
Hard disk drives installed on the Expansion File Unit Type-2 are hot-swappable. To enable hot-swapping, use the
tools (machine administration) contained in the "Enhanced Support Facility" to perform hot-swapping while
monitoring the state of the ACTIVE, FAULT and CHECK LEDs. For details on how to swap hard disk drives,
refer to the "Machine Administration Instructions" included with the "Enhanced Support Facility".