12.2 RCI Commands
Example of how to use commands
Set the MODE switch on the PRIMEPOWER Server to MANUAL and connect the RCI cable.
Then turn the power on and enter the following commands from the ok prompt.
To initially connect units, enter the following commands:
1 ok rci-config 1 1
2 ok rci-configio-init
To add I/O units later on, enter the following command:
1 ok rci-configio
To add host nodes, enter the following commands:
1 ok rci-config n m
2 ok rci-configio
Where "n" is the node address of the connected I/O, and "m" is the number of host nodes.
After making the above settings, execute the rci-config command to check that the settings have
been made correctly. After set-up is complete, return the MODE switch to the regular operation
setting (AUTO or SECURE).
229