System Configuration Guide
PRIMEQUEST 2800B3
200V High Efficiency PSU
MC-5HPS41 / MCX5HPS41 (LD)
- Min 3 - Max. 6 units per Base Unit
- 80PLUS® Platinum certified
200V Normal PSU
MC-5HPS61 / MCX5HPS61 (LD)
- Min 3 - Max. 6 units per Base Unit
- 80PLUS® Sliver certified
Fan unit
MC-5HFA41 / MCX5HFA41 (LD)
- Fan unit x 1
Power Cords for Base Unit
PSU Fan Power cord
Not redundant
3
3 3
3
AC 200V redundant (*1)
Dual redundant (*2)
6 (3×2)
6 0
(*1) Single power feed configuration will help to supply power even in the event of PSU failure.
(*2) Dual power feed configuration will help to supply power even in the event of one Power feed failure or PSU failure.
MMB #0
PSU/
FAN #0
PSU/
FAN #1
PSU/
FAN #2
PSU/
FAN #3
PSU/
FAN #4
PSU/
FAN #5
I/O Unit #0
PCI Slot
LAN port
I/O Unit #2
PCI Slot
LAN port
I/O Unit #1
PCISlots
LAN Port
I/O Unit #3
PCI Slot
LAN Port
Disk Unit #0
HDD
RAID
Card
Disk Unit #1
HDD
RAID
Card
SB #2
CPU CPU
Memory
Memory
SB #1
CPU CPU
SB #3
CPU CPU
Memory Memory Memory Memory
SB #0
CPU CPU
Memory
Memory
RAID
Card
RAID
Card
Total number of PSUs and Fans to be mounted needs to be six.
Fans need to be mounted for PSU slots for cooling if they are unoccupied.
FUJITSU Server PRIMEQUEST 16 / 28