104 Operating Manual BX900 S1
Hot-plug components
© cognitas. Gesellschft für Technik-Dokumentation mbH 2010 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-4953-006.fm
2 Stack indicator (green/yellow) (future use)
Lit yellow: Operating as a stack master
Flashes yellow: Operating failure as a stack master
Lit green: Operating as a stack slave
Flashes green Operating failure as a stack slave or during master
election process
Dark: No stacking
3 ID indicator (blue)
Lit: ID LED was activated via the management blade
Dark: Normal operation
6 Hidden reset button
A 10-Gbit Ethernet ports for SFP+ modules for connection of fiber-optic cables or
for active twinax copper cables (each with two integrated status LEDs)
4 (ERR)
Error indicator (orange)
Dark: No SFP+ module error or SFP+ module not installed
Lit: SFP+ module error
Flashes: SFP+ module not supported
5 (LINK)
LAN connection indicator (green)
Lit: LAN connection available
Flashes: LAN connection active
Dark: LAN connection unavailable or deactivated

Table of Contents