© 2011 Fujitsu Technology Solutions
Error Message Error: Could not create the MST instance.
Explanation The Spanning-Tree MST ID already existed.
Recommended Action Create Spanning-Tree MST ID which is not used.
Error Message Error: MST ID format is invalid.
Explanation The value of Spanning-Tree MST ID is not numeric character.
Recommended Action Set Spanning-Tree MST ID with numeric character 1 to 4094.
Error Message Error: Value (<value>) is out of range for MST ID. The valid
range is 1 to 4094.
Explanation The value of Spanning-Tree MST ID is out of range.
Recommended Action Set Spanning-Tree MST ID with numeric character 1 to 4094.
Error Message Error: Priority format is invalid.
Explanation The value of Spanning-Tree MST Priority is not numeric
character.
Recommended Action Set Spanning-Tree MST Priority with numeric character 0 to
61440.
Error Message Error: Value (<value>) is out of range for Priority. The valid range
is 0 to 61440.
Explanation The value of Spanning-Tree MST Priority is out of range.
Recommended Action Set Spanning-Tree MST Priority with numeric character 0 to
61440.
Error Message Error: Failed to set Priority. You entered <priority_value>.
Explanation The Spanning-Tree MST Priority is associated with invalid
instance.
Recommended Action Refresh the WEB page, and select the instance again.
Error Message Error: Priority was set successfully to a value in accordance with
IEEE 802.1s specifications.
Explanation User input a wrong Spanning-tree Priority, system will change to
the correct value automatically, and pop-up the warning
message.
Recommended Action
No recommended action. According to the IEEE802.1s
specification, the priority is a multiple of 4096. For example, 0,
4096, 8192, and the default priority is 32768.