Connecting the Embedded Switch Module to the Ethernet network
3
5. Perform the appropriate action based on whether you are using DHCP.
If you are using DHCP, enable it by selecting DHCP enable and clicking Apply.
If you are not using DHCP, uncheck the DHCP Enable check box, enter the appropriate
information in the IP Address, Subnet Mask, and Gateway fields, and click Apply.
6. Click the Reload Settings button to view the new IP address. It could take up to three minutes
for the settings to reload.
NOTE
Refer to the PRIMERGY BX900 Management Blade User Guide for additional details.
Connecting the Embedded Switch Module to the Ethernet network
The Embedded Switch Module has one external port and two internal ports that interact with the
chassis. Once you have successfully set the appropriate IP address of the Embedded Switch
Module, you can establish an Ethernet connection using one of two methods:
The PRIMERGY BX900 Management Blade application through an internal port.
Through the external Fabric port.
Connecting the Embedded Switch Module through an internal port
The internal Ethernet connection is the default configuration and no action is required.
Figure 10 shows the default port control setting on the PRIMERGY BX900 Management port.
FIGURE 10 PRIMERGY BX900 Management Port Control defaults to Internal Port