9.2.2.3 Out-of-Band Mgmt
Out-of-Band Mgmt interface provides a network access connection via MMB’s service port.
Figure : Out-of-Band Mgmt Config
You use this panel to specify the parameters needed to communicate with the switch over a network
using the Out-of-Band Mgmt.
Selection Criteria
IPv6 Mode - Enable/Disable IPv6 stack for out-of-band mgmt interface.
OOB Interface Configured Protocol - Choose what the switch should do following power-up:
transmit a Bootp request, transmit a DHCP request, or do nothing (none). The factory default is
DHCP. You cannot make this choice for both the In-Band Mgmt and the Out-of-Band Mgmt. You will
only be given the choices for “None” here if the In-Band Mgmt is configured to “Bootp” or “DHCP”.
DHCP6 Client - Selects if the DHCP6 Client is enabled or disabled. You cannot make this choice for
both the In-Band Mgmt and the Out-of-Band Mgmt. You will only be given the choices for Enable
here if the In-Band Mgmt is configured to Disable.
Configurable Data
IP Address - The IP address of the interface. The factory default value is 0.0.0.0.
Subnet Mask - The IP subnet mask for the interface. The factory default value is 0.0.0.0.
Default Gateway - The default gateway for the IP interface. The factory default value is 0.0.0.0. You
cannot set default gateway for both the In-Band Mgmt and the Out-of-Band Mgmt. You can modify
the gateway here if the gateway of In-Band Mgmt is configured to 0.0.0.0.