56 Operating Manual RX600 S5
Connecting the server to the mains Hardware installation
© cognitas. Gesellschft für Technik-Dokumentation mbH 2010 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-4887-003.fm
Installation requirements for AC non redundant configurations
For systems not requiring AC redundancy, the power supply subsystem can be
installed with up to 4 PSUs. The PSUs can be connected to a single or multiple
AC sources.
Three power supply modules are capable of handling the maximum power
requirements for a fully configured PRIMERGY RX600 S5 server system, which
include the following:
Four processors
1024 GB of memory
Eleven PCIe add-in cards (including the SAS/SATA RAID controller card)
Eight hard disk drives
One optical drive
One tape drive
The hot swap feature allows the user to replace a failed power supply module
without affecting the system functionality.
PSU Configuration Max. DC Loading DC Redundancy
1+1 (2 PSUs) 830W Yes
2+1 (3 PSUs) 1580W Yes
3+1 (4 PSUs) 2320W Yes
Table 3: Maximum DC Loading Requirements