Page #146 background image
Compressor status output
Signal on compressor operation status is generated when the compressor is running.
Circuit diagram example
Outdoor unit
control PCB
Example:
Relay unit
Connected unit (Locally purchased)
Example: Fan
Signal
Connector
1
2
1
2
10m*
12 V
On/
Off
P590
On/
Off
PA590
Output voltage (Vcc): DC 12 V
50 mA or less
*: Make the distance from the
PCB to the connected unit with-
in 10 m.
Operation
Stop
On
Off
Compressor
status
Output signal
Optional part
Part name Model name Exterior
External connect kit UTY-XWZXZ3
External output wire
- 138 -