B-18 SPARC Enterprise M8000/M9000 Servers Service Manual June 2010
FIGURE B-12 eXtended System Control Facility Unit (XSCFU_C)
XSCFU has the following characteristics.
The XSCFU has a duplicated configuration as the standard specification, allowing
hot replacement of a failed XSCFU during system operation.
XSCFU is the central control unit of the system and has the following functions:
It controls each unit.
It works as the console of each domain by using the TTY communication
protocol.
It communicates with each domain by using the command-line interface.
It manages the device information.
It supports the browser-based user interface (BUI) function called XSCF Web.
It allows connection to maintenance terminals.
It supports remote maintenance services.
It allows interlocking control for power supply and cluster control by using a
remote cabinet interface (RCI).
The XSCFU has a label bearing the printed component number and manufacture's
serial number.