EasyManua.ls Logo

Fujitsu Waterstage Split Comfort 5 Series - Page 30

Fujitsu Waterstage Split Comfort 5 Series
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 30 -
Additional lling
The amount needed to ll the outdoor units corresponds to the maximum distances between the outdoor unit and
the hydraulic unit as de ned here page 28. If the distances are greater, an additional amount of R32 is required.
For each type of appliance, this additional amount depends on the distance between the outdoor unit and the
hydraulic unit. Any additional lling with R32 must be carried out by an approved specialist.
Model 5, 6, 8 (Outdoor unit WOYA060KLT, WOYA080KLT)
15m < Length of the connections 30m
(Length of the connections - 15m) x 25 g/m= g
Model / Factory ll
Length of the
connections in m
16 17 X 29 30
Model 5, 6 / 970 g
Fill amount in g
995 1020 970 + (X - 15) x 25 = g 1320 1345
Model 8 / 1020 g 1045 1070 1020 + (X - 15) x 25 = g 1370 1395
Model 10 (Outdoor unit WOYA100KLT)
20m < Length of the connections 30m
(Length of the connections - 20m) x 20 g/m= g
Model
... /
Factory
ll
Length of the
connections in m
21 22 X 29 30
Model 10 / 1630 g Fill amount in g 1650 1670
1630 + (X - 20) x 20
= g
1810 1830
Filling must be carried out after creating a vacuum and
before gassing the hydraulic unit, as follows:
- Disconnect the vacuum pump (yellow hose) and
connect a bottle of R32 in its place in the liquid
extraction position.
- Open the bottle’s valve.
- Bleed the yellow hose by loosening it slightly on the
Manifold side.
- Place the bottle on scales with a minimum accuracy of
10g. Note the weight.
- Carefully open the blue valve slightly and check the
value shown on the scales.
- As soon as the value displayed has dropped by the
value for the calculated additional ll amount, close the
bottle and disconnect it.
- Quickly disconnect the hose connected to the
appliance.
- Proceed to ll the hydraulic unit with gas.
Only use R32 !
Only use tools suitable for R32
(set of pressure gauges).
Always ll in the liquid phase.
Never exceed the maximum length or
di erence in level.
R32
Liquid
Gas
g. 35 - Gas bottle R32
Waterstage Split Comfort DHW Serie / INSTALLATION / 2125 - EN