- 69 -
Outdoor Unit : model 10
When an error occurs:
- The LED "ERROR" (2) blinks.
- Press once on the switch "ENTER" (S132).
- The LED blinks several times depending on the error's
type (see below).
(1)
POWER
MODE
ERROR
MODE
S134 S133 S132 S131 S130
ERROR CLR
INITIALIZE
SELECT ENTER EXIT
PUMP DOWN
PUMP
DOWN
L1 L2 L3 L4 L5 L6
LOW
NOISE
PEAK
CUT
(2) (3) (4) (5)
Error
Outdoor Unit Board
Error designation
(L1) (L2) (L3) (L4) (L5) (L6)
11
11ΟΟ Serial communication error after operation
11Ο●ΟΟSerial communication error during operation
23 2 3 ΟΟΟ Di erent combinations used by indoor and outdoor units
62 6 2 ΟΟΟ Outdoor unit main PCB error
63 6 3 ΟΟΟ Inverter error
65
65ΟΟ Outdoor unit IPM error
65ΟΟΟ IPM board temperature error
71 7 1 ΟΟΟ Discharge thermistor error
72 7 2 ΟΟΟ Compressor thermistor error
73
73ΟΟ ΟHeat-exchange thermistor (intermediate) error.
73ΟΟ Heat-exchange thermistor (outlet) error.
74 7 4 ΟΟΟ Outdoor thermistor error
77 7 7 ΟΟΟ Outdoor unit heat sink temp. thermistor error
78 7 8 ΟΟΟ Expansion valve thermistor error
84 8 4 ΟΟΟ Current sensor error
86
86Ο●ΟΟPressure switch error
86Ο● ●ΟPressure sensor error
94 9 4 ΟΟΟ Trip detection
95 9 5 ΟΟΟ
Detection of compressor position error
Compressor start up error
97 9 7 ΟΟ Outdoor unit fan1 motor error
A1 10 1 ΟΟΟ Discharge temperature protection
A3 10 3 ΟΟΟ Compressor temperature protection
A5 10 5 ΟΟΟ Low pressure abnormal
AC 10 12 ΟΟ Outdoor unit radiator temperature error
: LED Off ; : LED on
Waterstage Split Comfort DHW Serie / INSTALLATION / 2125 - EN