Split system (Single phase and 3-phase type)
50 Maintenance Document 1544-1
COMMAND
LINE
ACCESS
LEVEL
FUNCTION SETTING RANGE
FACTORY
SETTING
2873 S
Compressor mod run time
10…240s 240
2882 S Release integr electric flow 0… 500°Cmin 100°Cmin
2884 S Release el flow at OT -30°C…30°C 2°C
2886 S Compensation heat deficit
Off ¦ On ¦ Only with
floor curing fct
Off
2916 S Max setpoint HP DHW charg 8°C… 80°C 60°C
2920 S With electrical utility lock Lock/release Released
Supplementary source
3700 S Release below outside temp -50…50°C 2°C
3701 S Release above outside temp -50…50°C
3705 S Overrun time 0...120min 20min
3720 S Switching integral 0… 500°Cmin 100°Cmin
3723 S Locking time 0...120min 30min
DHW storage tank
5024 S Switching differential 0…20°C 7°C
5030 S Charging time limitation 10…600min 90 min
5055 S Recooling temp 8…95°C 65°C
5057 S Recooling collector
Off ¦ Summer ¦ Always
Summer
5061 S Electric immersion heater release
24h/day
DHW release
Time program 4/DHW
DHW release
5093 S Not used
Configuration
5700 I Pre-setting 1 to 12 1
5710 I Heating circuit 1
Off ¦ On
On
5711 I Cooling circuit 1
Off
4-pipe system
2-pipe system
Off
5715 I Heating circuit 2
Off ¦ On
On
5731 I DHW ctrl elem Q3
No charging request ¦
Charging pump ¦
Diverting valve
Diverting valve
5806 I Type el imm heater flow
1 : 3-stage, 2 : 2-stage
excluding, 3 : 2-stage
complementary, 4 :
Modulating UX
3 : 2-stage
complementary
5981 S Cont type input EX1
NC ¦ NO
NO
5983 S Cont type input EX2
NC ¦ NO
NC
5985 S Cont type input EX3
NC ¦ NO
NO
6098 S Not used -20…20°C 0°C
6100 S Readjustm outside sensor -3…3°C 0°C
6120 S Frost protection plant On/off On
6205 S Reset to default parameters No/yes No
6220 S Software version 0…99 --
6420 I
Function input H33
Optg mode change HCs+DHW ¦ Optg mode changeover DHW ¦ Optg mode changeover HCs ¦
Optg mode changeover HC1 ¦ Optg mode changeover HC2 ¦ Optg mode changeover HC3 ¦
Error/alarm message ¦ Release swi pool source heat ¦ Release swi pool solar ¦ Dewpoint
monitor
6421 I Contact type H33
NC ¦ NO
NO
LPB system
6600 I Not used 0…16 1
Errors
6711 U Reset HP No/yes No
6800 S History 1 Date/time/code
6802 S History 2 Date/time/code
6804 S History 3 Date/time/code
6806 S History 4 Date/time/code
6808 S History 5 Date/time/code
6810 S History 6 Date/time/code
6812 S History 7 Date/time/code