Heating circuit 1 & 2 functions
z
Operating Mode
For heating circuits there are several functions
available which can be individually adjusted for
each heating circuit.
The programming lines for the 2nd heating circuit
are displayed only if the extension module has
been connected to the controller.
Operation of heating circuits 1 and 2 is directly
controlled via the operating mode key.
Setpoint Values
LINE FUNCTION
HC1 HC2
710 1010 Comfort setpoint
712 1012 Reduced setpoint
714 1014 Frost protection setpoint
716 1016 Maximum comfort setpoint
Room temperature:
Room temperature can be set according to different
setpoint values. Depending on the selected mode,
these setpoints are activated and provide different
temperature levels in the rooms.
The ranges of congurable setpoints are dened
by their interdependencies, as shown in the graph
below.
Comfort setpoint
Comfort setpoint max
Reduced setpoint
Frost prot. setpoint
Frost protection:
The protection mode automatically prevents an
excessively sharp drop in room temperature.
In this case the control adopts the frost protection
room setpoint.
Heating Curve
LINE FUNCTION
HC1 HC2
720 1020 Heating curve slope
721 1021 Heating curve displacement