SPECIFICATIONS2.
NOMINAL CAPACITY AND NOMINAL INPUT2-1.
Model name (Outdoor unit) WO
Û
K112LCT WO
Û
K140LCT WO
Û
K160LCT
POWER SOURCE 3Ø 400V/50Hz
+7°C/+35°C
floor heating
Heating capacity
Minimum
kW
6.20 6.20 6.20
Nominal 10.80 13.50 15.17
Maximum 19.50 21.00 22.00
Input power
Nominal
2.51 3.20 3.70
COP - 4.30 4.22 4.10
+7°C/+45°C
radiators
Heating capacity
Nominal
kW
10.10 12.60 13.00
Input power 3.01 3.81 4.00
COP - 3.35 3.30 3.25
+2°C/+35°C
floor heating
Heating capacity
Nominal
kW
10.77 13.00 13.50
Input power 3.40 4.15 4.34
COP - 3.17 3.13 3.11