- (OU01 - 04) -
Outdoor unit / Single phase
OUTDOOR UNIT
WO
G112-140LCTA
OUTDOOR UNIT
WO
G112-140LCTA
SPECIFICATIONS2.
NOMINAL CAPACITY AND NOMINAL INPUT2-1.
Model name (Outdoor unit) WO
Û
G112LCTA WO
Û
G140LCTA
POWER SOURCE 1Ø 230V.~ 50Hz
+7°C/+35°C
floor heating
Heating capacity
Minimum
kW
6.20 6.20
Nominal 10.80 13.50
Maximum 16.70 19.60
Input power
Nominal
2.54 3.23
COP - 4.25 4.18
+7°C/+45°C
radiators
Heating capacity
Nominal
kW
9.05 11.32
Input power 2.82 3.69
COP - 3.21 3.07
+2°C/+35°C
floor heating
Heating capacity
Nominal
kW
10.77 12.00
Input power 3.44 3.87
COP - 3.13 3.10
* Test conditions comply with EN14511-2