SSTEv2Specifications
Impedance‐
Inputimpedance‐1.1megaohms
OutputimpedanceswitchsettoBuffered(BUF)‐10kohms
OutputimpedanceswitchsettoBuffer‐Bypass(BYP)‐220K‐500K(dependingonwheretheECHO
VOLUMEknobisset)
Size‐
9.56”widex7.8”deepx6.3”tall(withlidonandclosed)
Weight‐
9.2lbs.
Tapeformat‐
YoumayonlyusetheFulltoneEchoTapeCart(ETC‐2)anormalEchoplexcartisthewrongsize.
CartsmadefortheTTEandEchoplexwillNOTfunctioninaSSTE.
WetrytoonlyuseBASFLGR‐50tapeforourCartswhichisnolongermade,butIhavemanythousands
ofyardsofit,enoughfor30yearsormore.Itisoneoftheonlytapesthatworksbecauseithasawhite
lubricatedbacking,helpingtokeepthetapefromsticking,thenbinding.
YoumayalsousetheFulltoneTapeLoopTransport(TLT),givingthechoiceofusinganyavailable¼”
tape.Makethetapeloopexactlytherecommendedlength(seeTLTbox)
Electricalinfo‐
100‐120VAC,60hz,6watts.
Thewiringforthetransformercanbeeasilymodifiedfor220/240VAC50hzoperationinsidetheunit.
Fuse‐
0.25amp/250mA5mmx20mmglassSlow‐Blowfuse.
Included‐
1xDetachable10’IECtypeACpowercable
1x3‐to‐2PronggroundliftadapterforACpowercable
1XETC‐2Tapecartridge(pre‐installedinSSTE)
Optional:Echo‐CancelFootswitch‐
TocanceltheechoonaSSTEv2,youcanusealatching“ampchannelswitcher”footswitchthat
groundsouttheTIPofa¼”malephonoplug.But,ifyouwanttohaveLEDstatusindicatorswithout
havingtosupplyanypower,theonlyfootswitchtogetistheFulltoneEchoCancelFootswitch.Get