Do you have a question about the Furman AR-1215 and is the answer not in the manual?
output current rating | 15 amperes for input voltages of 124V |
---|---|
initial turn-on voltage | 200V |
maximum surge current | 6, 500 amps |
regulation range | ±5V from 97V to 141V |
---|---|
shutdown range | below 75V or above 150V |
voltmeter accuracy | ±5V |
spike clamping voltage | 400 volts peak at 500 A |
---|---|
maximum spike energy | 80 joules per node; 240 joules total |
noise attenuation | 20 dB at 200 kHz, rising to >40 dB, 1 to 100 MHz |
dimensions | 1.75” H x 19” W x 8.5” D |
---|---|
weight | 12 lbs. (5.5 kg) |
output current rating | 15 amperes for input voltages of 124V |
---|---|
initial turn-on voltage | 200V |
maximum surge current | 6, 500 amps |
regulation range | ±4V from 82V to 115V |
---|---|
shutdown range | below 65V or above 135V |
voltmeter accuracy | ±4V |
spike clamping voltage | 400 volts peak at 500 A |
---|---|
maximum spike energy | 80 joules per node; 240 joules total |
noise attenuation | 20 dB at 200 kHz, rising to >40 dB, 1 to 100 MHz |
dimensions | 1.75” H x 19” W x 8.5” D |
---|---|
weight | 12 lbs. (5.5 kg) |
output current rating | 6 amperes for input voltages of 228V/238V/248V |
---|---|
initial turn-on voltage | 390 volts peak L-N; 680 volts peak N-G, L-G |
regulation range | ±10V in the following ranges: 174-264V (220 mode), 181-276V (230 mode), 190-288V (240 mode) |
---|---|
shutdown range | below 146V or above 279V (220 mode); below 152V or above 287V (230 mode), below 158V or above 300V (240 mode) |
voltmeter accuracy | ±10V |
spike clamping voltage | 400 volts peak at 500 A |
---|---|
maximum spike energy | 130 joules L-N, 160 joules N-G, L-G, 450 joules total |
noise attenuation | 20 dB at 200 kHz, rising to >40 dB, 1 to 100 MHz |
dimensions | 1.75” H x 19” W x 8.5” D |
---|---|
weight | 12 lbs. (5.5 kg) |
Read and observe all safety and operating instructions before operating the AR-1215 or AR-2306.
Do not use the AR-1215 or AR-2306 near water, such as bathtubs, sinks, or swimming pools.
Avoid placing the AR-1215 or AR-2306 near heat sources like radiators or stoves.
Route power and other cables to prevent tripping hazards.
Defines AC line voltage and how a regulator corrects deviations by stepping voltage up or down.
Describes power line spikes, their high voltages, and potential to damage sensitive electronic components.
Explains RFI/EMI noise, its lower voltage/energy, and effects on audio, video, and computer systems.
Circuitry senses over/undervoltages and shuts down output to prevent damage.
High voltages over approx. 300V blow an internal fuse, protecting equipment.
A 15A [6A] breaker trips if capacity is exceeded, accessible at the rear panel.
A 1/4 amp fuse protects against voltages above the Extreme Voltage Shutdown range.
Ten LEDs on the front panel indicate input voltage levels, with red LEDs for out-of-range conditions.
A green LED indicates the output voltage is within ±5V [±10V] of the selected output voltage.
Suggests top or bottom rack locations; use 10-32 screws and plastic washers for mounting.
Assures minimal magnetic field leakage, high efficiency, and compact size for its rating.
Electronically switches taps at zero-crossing to avoid distorting the AC waveform.
Details current ratings for AR-1215 (15A) and AR-2306 (6A) with derating information.
Specifies the input voltage ranges for ±5V (AR-1215) and ±10V (AR-2306) regulation.
Defines the voltage limits for AR-1215, AR-1215J, and AR-2306 that trigger shutdown.
States the accuracy of the input voltage voltmeter for different models.
Covers spike clamping voltage, response time, and maximum surge current.
Specifies noise attenuation levels for transverse and common modes.
Provides the physical dimensions (HxWxD) and weight of the unit.