EasyManua.ls Logo

Furuno 1715 - Chapter 3 Adjustment; Display Unit; Scanner Unit

Furuno 1715
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3 Adjustment
13
DANGER- High voltage
The display unit contains 1 kVAC for LCD backlighting and
the scanner unit 300 VDC for TX.
3.1 Display unit
+5 V is adjusted by VR1 on DU board. See Fig.3-1 for the location of parts.
Table 3-1 Test points of Display unit
Item Setting Test point Ratings Adjuster
+5 V TX (8 NM) TP4 (+), TP5 (-) 4.95 to 5.05 Vdc VR1
+12 V ST-BY J1#7 (+), J1#5 (-) 11.2 to 12.4 Vdc
-22 V ST-BY J1#10 (+), J1#5 (-) -22.9 to -20.7 Vdc
-6 V ST-BY J1#9 (+), J1#5 (-) -6.0 to -5.0 Vdc
Fig.3-1 Location of J1 and J8 on DU board
3.2 Scanner unit
Adjusters on MD board in the scanner unit are adjusted as below.
Table 3-2 Test points of Scanner unit
Item Setting Test point Rating Adjuster
+12 V ST-BY
TP804#3 (+)
TP804#4 (-)
11.9 to 12.1 Vdc VR801
+8 V
heater volt.
ST-BY
TP804#6 (+)
TP804#4 (-)
7.8 to 8.2 Vdc
TX-HV
(divided)
ST-BY
TP804#7 (+)
TP804#4 (-)
8.5 to 9.35 V
Long 3.05 to 3.15 V VR851
Magnetron
current
TX
TP804#5 (+)
TP804#4 (-)
Short 3.35 to 3.45 V VR852
TP2
DU Board
(03P9320)
J8
J1

Other manuals for Furuno 1715