4.5 Magnetron
18
4.5 Magnetron
When handling the magnetron, taking the followings into account not to damage the magnetron
physically and electrically.
1) Use a non-magnetic screw driver to dismount and mount the magnetron.
2) Keep the magnetron 25 mm away from the metals.
3) Never pull the magnetron lead wires.
4.6 MIC
See Fig.4-8. Remove the MIC shorting plug before use.
Remove MIC shorting plug.
Dowels
Dowels
M4 X 20
M4 X 10 4pcs.
Fig.4-8
S-RX50A
U801
V801 Magnetron
E3588