APPENDIX
AP-3
6. Clean the top of the main shaft with alcohol, apply bond “Lock-tight 601” and install the
waterproof attachment.
Clean with alcohol
and apply Lock-tight.
30 mm
Shaft
Waterproof
attachment
· Tighten the M6 socket-set screws with a torque of 3.92 N·m to 4.9 N·m.
7. Assemble the hull unit completely, taking the following points into account.
1) The shaft retainer should be in contact with the waterproofing attachment.
2) The fastening band should not be used on the main shaft fitted with the
waterproofing attachment is used.
3) When the main shaft is installed without cutting, position the shaft retainer as
below.
L = Cut length shown on page AP-5 + 30 mm.