2-1
2. WIRING
Refer to the interconnection diagram at the back of this manual to connect cables.
Note: For details of JIS (Japan Industrial Standard) cables, see "JIS CABLE
GUIDE" on page AP-4.
Precautions for cable installation
Observe the following guidelines to prevent noise, interference problem.
• The transducer cable carries very weak signals (amplitude less than 0.1 V), which
are easily interfered by noise. The need for a good ground cannot be overempha-
sized. Pass the transducer cable through dedicated conduit. Fill the conduit with vi-
bration absorbing material (sand, etc.) to prevent vibration. The part of the cable ex-
tending from the conduit should be as short as possible. Separate the transducer
cable at least 40 cm from other cables.
• Locate DS-60 cables away from the transmission antenna cable or radio equip-
ment.
• Locate the DS-60 cables away from the power cables mentioned below. Also, sep-
arate cables at least 40 cm when the cables are run parallel with power cables.
• Cable carrying more than a few kilowatts power to fluctuating loads
• Cable carrying switching waves generated by thyristor, etc.
TTYCYS-4 or TTYCS-4
(Max. 150 m)
Distributor
DS-610
Display Unit
(main)
DS-600
Remote Controller RD-501/
Dimmer Controller RD-502
TTYCS-4
Transducer cable
(30 m/40 m/50 m/60 m)
Transducer
DS-630/631/
630A/631A
Transceiver
Unit
DS-620
TTYCY-4S*
*The cable length between DS-620 and DS-610 must be less than 500 m.
100-240 VAC
(DPYC-2.5)
ANALOG VOLTAGE OUT (TTYCS-1)
ANALOG CURRENT OUT (TTYCS-1)
KP IN/OUT (TTYCS-1, x2)
ALARM SYSTEM
ANALOG METER OUT (TTYCYS-1Q, x2)
IEC61162/IN (TTYCS-1, x3)
IEC61162/OUT (TTYCS-1, x5)
Display Unit (sub) DS-600, RD-20/50 (x5)
LOG/CONTACT, 200 pulse (DPYCY-1.5, x4)
DS-670
(S66-9-5)
TTYCY-4S*
DPYCY-4.0*
DPYCY-4.0*
TTYCY-19S or
TTYCY-10S*
Junction
Box
(option)
DS-
645A
DS-
645B
DS-640