3. MENU SETTINGS
3-2
Menu item Meaning
Option
(default in
boldface)
[Operation] Select [Main], [Sub] or [Satellite] to
use.
For display units connected to TB7
in the DS-610, select [Main].
For sub display units connected to
a GS-100 and DS-60 (dual input),
select [Satellite].
[Main], [Sub], [Sat-
ellite]
[Alarm Mode] Select the alarm mode. (Select
[Alert I/F1] or [Alert I/F2] when
connected to AMS.)
[Legacy],
[Alert I/F1],
[Alert I/F2]
[Buzzer Stop] Select the signal to input to TB8
#11 and #12 of DS-610 (main dis-
play only).
Note: This item is grayed out (inop-
erative) when [Alarm Mode] is [Alert
I/F1]or [Alert I/F2].
[Enable]: Stop the audible alarm at
the external equipment. To “ACK”
the alarm, press the ALARM ACK
key.
[Disable]: Stop the audible alarm
and “ACK” the alarm at the external
equipment.
[Enable],
[Disable]
[Output Data Format] Select the version of IEC61162
data to output from DS-610.
[IEC61162-1 Ed.2]
[IEC61162-1 Ed.3]
[IEC61162-2 Ed.1]
[IEC61162-1 Ed.4]
[Input Data
Format]
[IEC] [61162_IN_1] Select IEC data format input to the
channel 1 of the IN port, TB2-#1, 2
in DS-610. (main display only)
[IEC61162-1 Ed.2]
[IEC61162-1 Ed.3]
[IEC61162-2 Ed.1]
[IEC61162-1 Ed.4]
[61162_IN_2] Select IEC data format to input to
the channel 2 of the IN port, TB2-
#3, 4 in DS-610. (main display only)
[61162_IN_3] Select IEC data format to input to
the channel 3 of the IN port, TB2-
#5, 6 in DS-610. (main display only)
[NMEA] [61162_IN_1] Select NMEA data baud rate to in-
put to the channel 1 of the IN port,
TB2-#1, 2 in DS-610. (main display
only)
[4800]
[38400]
[61162_IN_2] Select NMEA data baud rate to in-
put to the channel 2 of the IN port,
TB2-#3, 4 in DS-610. (main display
only)
[61162_IN_3] Select NMEA data baud rate to in-
put to the channel 3 of the IN port,
TB2-#5, 6 in DS-610. (main display
only)
[IEC61162 IN Monitor] Monitor the IEC input signal described above. (main dis-
play only)
[SIO Monitor] Monitor the serial signal input to the display units. (main
and sub)

Other manuals for Furuno DS-60