Furuno DS-80 - IEC61162 RX PORT SCHEMATICS; IEC61162 TX1 PORT SCHEMATICS

Furuno DS-80
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
Schematic diagrams
IEC61162 RX port
DS-801
65P6010
11
12
.
.
.
.
.
.
TB3
F2047A-20P-B
IEC61162_RX_A
IEC61162_RX_B
<11<
<12<
JP6
ERJ_6GEY0R00V
R121 22
R122 120
R123 120
R124 22
1
2
CR17 1SS181
4
5
6
1
3
JP7
ERJ_6GEY0R00V
PC400
U42
Load requirements as listener
Isolation: Optocoupler
Input Impedance: 44 ohms
Max. Voltage: ±2.6V
Threshold: 4 mA
IEC61162 TX1 port
Output drive capability
Max. 20 mA