2. WIRING
2-5
On USB cable connection
Depending on your power supply (applied voltage), choose the correct cabling for
power input, referring to the table below.
2.1.2 Connecting the flush mountable USB extension cable
You may require an extension from the USB port on the PCU. A 1m length USB
extension cable is included with the PCU. When using another USB extension cable,
make sure the total length is shorter than 5 m.
You can connect the flush-mounted extension cable by doing the following:
Fasten the USB cable to the cable clamp with a cable tie (width: 5 mm).
The USB cable connected between USB1 and the Trackball Control Unit should be
separately fastened to the cable clamp.
Observe the following points with regards to the keyboard.
When no keyboard is connected, do not connect equipment to USB3. Further,
separately fasten the extension cable from USB4 to the USB cable clamp, using a
cable tie.
When a keyboard is connected, bind the keyboard cable together with the ex-
tension cable from USB4 to the USB cable clamp.
Voltage Cable Description
230 VAC TP52/TC01 cable Type F “Schuko”, included with PCU-3010.
100 VAC TP11/TC01 cable Type B, included with PCU-3010.
24 VDC DPYC-1.5 cable
(JIS cable)
See paragraph 2.1.3 for how to fabricate the
power cable.
IEC
EUR TYPE F
US TYPE B
IEC
Cap strap
USB extension cable