2. WIRING
2-12
2.1.6 Securing cables to the cable clamp
When installing the unit with the desktop option, use the cable clamp to secure the
electrical wiring, LAN cable, DC power cable, and video cable (3COX-2P-6C).
When not using the cable clamp, drain wires must be connected to the grounding
point on the PCU-3010 (See the figure in paragraph 2.1.1).
When using the cable clamp, connect the drain wires of cables to the screws circled
in the figure below. Fasten cables to the clamp with two cable ties for each cable. The
cable ties should be 5mm in width.
2.1.7 Alert interface types and maximum number of alert interfaces
The PCU-3010 has the following alert interface types and quantities:
IEC 61162-1/2 (2 ports)
IEC 61162-1 (2 ports)
IEC 61162-450 (1 port)
Cable clamp
DC Input
DPYC-1.5
LAN cable
FR-FTPC-CY
Video cable
3COX-2P-6C
Fasten drain wires here, using supplied crimp-on lugs and binding screws.
LAN cable
DTI-C5E350 VCV
Marine electrics
TTYCSLA-4
Marine electrics
TTYCSLA-1Q
Cable ties
(two per
each cable)