2. WIRING
2-15
Connector J5
Connector J6
Connector J7
Connector J8
Pin
#
Signal
name
In/
Out
Description IEC61162-2 IEC61162-1
1 TD2-A Out Serial CH2, output IEC61162-1/2/modbus TTYCS(LA)-4 TTYCS(LA)-4
2 TD2-B Out Serial CH2, output IEC61162-1/2/modbus
3 RD2-A In Serial CH2, input IEC61162-2/modbus No connec-
tion
4 RD2-B In Serial CH2, input IEC61162-2/modbus
5 ISOGND2 - Isolation, GND (CH2)
6 RD2-H In Serial CH2, input IEC61162-1 No connection TTYCS(LA)-4
7 RD2-C In Serial CH2, input IEC61162-1
Pin
#
Signal
name
In/
Out
Description IEC61162-2 IEC61162-1
1 TD3-A Out Serial CH3, output IEC61162-1/2 TTYCS(LA)-4 TTYCS(LA)-4
2 TD3-B Out Serial CH3, output IEC61162-1/2
3 RD3-A In Serial CH3, input IEC61162-2 No connection
4 RD3-B In Serial CH3, input IEC61162-2
5 ISOGND3 - Isolation, GND (CH3)
6 RD3-H In Serial CH3, input IEC61162-1 No connection TTYCS(LA)-4
7 RD3-C In Serial CH3, input IEC61162-1
Pin
#
Signal
name
In/
Out
Description IEC61162-2 IEC61162-1
1 TD4-A Out Serial CH4, output IEC61162-1/2 TTYCS(LA)-4 TTYCS(LA)-4
2 TD4-B Out Serial CH4, output IEC61162-1/2
3 RD4-A In Serial CH4, input IEC61162-2 No connection
4 RD4-B In Serial CH4, input IEC61162-2
5 ISOGND4 - Isolation, GND (CH4)
6 RD4-H In Serial CH4, input IEC61162-1 No connection TTYCS(LA)-4
7 RD4-C In Serial CH4, input IEC61162-1
Pin#
Signal
name
In/Out Description Used cable
1 TD5-A Out Serial CH5, output IEC61162-1 TTYCS-1Q or TTYCSLA-1Q
2 TD5-B Out Serial CH5, output IEC61162-1
3 RD5-H In Serial CH5, input IEC61162-1
4 RD5-C In Serial CH5, input IEC61162-1
5 TD6-A Out Serial CH6, output IEC61162-1
6 TD6-B Out Serial CH6, output IEC61162-1
7 RD6-H In Serial CH6, input IEC61162-1
8 RD6-C In Serial CH6, input IEC61162-1