1. OPERATIONAL OVERVIEW
1-94
Compatibility of display and operation
When connecting with FAR-2xx7 series radar
When switching the antenna from FAR-2xx8 to FAR-2xx7, the image for FAR-2xx7 is
displayed on the screen and each function is operative. However, when switching the
antenna from FAR-2xx7 to FAR-2xx8, the following functions are not operative.
Automatic Clutter Elimination (ACE) function.
Selection of the transmit frequency by the [TX CH] button for solid state radar.
Target Analyzer function.
• Hatching.
• Berthing STC.
1.48.3 How to clear the interswitch
You can clear the interswitch settings by following the procedure below.
1. Open the menu.
2. Select [9 INITIAL SETTINGS].
3. Select [3 SELECT ANTENNA]. The [SELECT ANTENNA] menu appears.
Note: You can also right-click the [ANTENNA] box to access this menu.
4. Select [0 CLEAR INTER-SWITCH].
5. Select [YES] to clear the interswitch settings. The antenna settings are restored
to default.
1.49 Performance Monitor
The performance monitor, installed in the antenna unit, produces a visual indication
on the radar display screen when the radar transmitter power and radar receiver sen-
sitivity are within the prescribed limits.
1.49.1 How to activate/deactivate the performance monitor
1. Set the radar to TX (transmit) mode.
2. Open the menu.
3. Select [1 ECHO].
4. Select [5 PERFORMANCE MONITOR].
5. Select the appropriate setting, then press the ENTER MARK key.
[OFF]: Deactivate the performance monitor.
Note: You can also deactivate the performance monitor by adjusting the range
manually.
[ON]: Activate the performance monitor and show the graph.
[GRAPH ONLY]: Show the performance monitor graph, however the perfor-
mance monitor is not activated.
6. Close the menu.
When the performance monitor is active, the indication "PM ×ARCS" (×: setting value
of [6 PM ARC]) appears in yellow characters at the top of the display.