2. WIRING
2-47
2.6 Power Supply Unit
2.6.1 How to fabricate cables
For locations of cables and cores, see the sticker on the reverse side of the top cover.
(All dimensions in millimeters)
For how to connect the LAN modular plug, see "LAN cable" on page 2-5. For how to
connect the WAGO connector, see "WAGO connector" on page 2-6.
RW-0013/RW-0030/03CA00099 (for Antenna cable)
<RW-0013/03CA00099>
<RW-0030>
6
30
330
200
14
14
5
*: For 03CA00099 cable, do not
fold the shield as shown in
the following.
Vinyl tape
Crimp-on lug
FV5.5-3,
supplied
Inner shield
Clamp position
(Wrap the outer shield a single time.)
NOTE:
Do not wrap the shield more than twice.
(unit: mm)
14
14
5
Folded shield
Fabrication of the coaxial cable
Inner shield
Coaxial cable
Outer shield
Outer sheath
6
(unit: mm)
1414
1414
55
Folded shield
Fabrication of the coaxial cable
200200
3030
Vinyl tape
330330
(
360
)(
360
)
Crimp-on lug
FV5.5-3,
supplied
Inner shieldInner shield
Inner shieldInner shield
Coaxial cableCoaxial cable
Outer shieldOuter shield
Clamp position
(Wrap the outer shield a single
time on the inner sheath.)
NOTE:
Do not wrap the shield
more than twice.
Outer sheath
Armor
Inner sheath