EasyManua.ls Logo

Furuno FAR-2238S-NXT-BB - Junction Box (Option)

Furuno FAR-2238S-NXT-BB
253 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. WIRING
2-72
2.11 Junction Box (option)
For FAR-2x18/2x28/2x38 X-band radars, the
Junction boxes are required when the dis-
tance between the Antenna Unit and Proces-
sor Unit is greater than 100 meters (max.
460 meters); for example, the Antenna Unit
is installed on the foremast. Use signal cable
RW-9600 (u2), power cable DPYCY-6 (u3),
and coaxial cable RG-12/UY(u3).
Pass each cable through its cable gland as
shown to the right.
Flat washer
Cable gland
Vinyl sheath
Clamping
gland
Gasket
Cut and trim armor.
15 14 13 12
11
10
98
7
65
4
3
21
RG12/UY
RG-12/UY
DPYCY-6
RW-9600/6895/4873
Connect inner conductors.
M8 screw for grounding
Clamp outer conductor of coaxial cables.
Fix wires with cable ties.

Other manuals for Furuno FAR-2238S-NXT-BB

Related product manuals