3. ADJUSTMENTS
3-6
Set the value so that noise just disappears from the screen. The setting range is -32
to +32 (default: +32).
Note: The setting range is 0 to +31 (default: +12) when the [MODEL] setting is set to
[50], see "[MODEL]" on page 3-12.
When using the number keys, the indication is first selected as a whole. At this time,
you can toggle between plus "+" or minus "-". Press the 8 key for "-", press the 2 key
for "+". If single digits are highlighted, toggle is not possible. In this case, press the
CANCEL/TRAILS key to re-highlight the whole indication.
[RING SUPPRESSION]
Remove “ring” noise which appears with the waveguide type radars. Adjust so the
rings disappear at the range of 0.125 m. The setting range is 0 to 255 (default: 1).
Note: This menu is NOT available when the [MODEL] setting is set to [50] (see
"[MODEL]" on page 3-12).
[VIDEO CONTRAST]
Select [ADVANCE] to clarify the echo image difference (default: [ADVANCE]).
[CLOSE TGT ES MODE]
The [ECHO STRETCH] menu can enlarge the whole targets of the screen (Main menu
o [ECHO] o [CUSTOMIZED ECHO] o [ECHO STRETCH]). This [CLOSE TGT ES
MODE] feature can also enlarge targets around own ship in addition to the [ECHO
STRETCH] feature.
This menu has three options, [ES1], [ES2] or [ES3]. Select the setting to enlarge the
targets around own ship for the [ECHO STRETCH] setting ([1] to [3]).
• [ES1]: Select when enlarging the targets around own ship with selected [1] at
[ECHO STRETCH].
• [ES2]: Select when enlarging the targets around own ship with selected [2] at
[ECHO STRETCH].
• [ES3]: Select when enlarging the targets around own ship with selected [3] at
[ECHO STRETCH].
Note: Multiple selections among [ES1], [ES2] and [ES3] are possible.
CONTRAST
LEVEL
CONTRAST
LEVEL
CONTRAST
LEVEL
CONTRAST
LEVEL
A
B C
[
VIDEO CONTRAST
]
set to
[
ADVANCE
]
at installation:
[
VIDEO CONTRAST
]
set to
[
LEGACY
]
at installation:
CONTRAST
C
B
A
CONTRAST
33
22
444
11
33
22
11
44