3. ADJUSTMENTS
3-22
[AIS], [WIND], [CURRENT], [WATER TEMP], [DEPTH]
Select the input source for each data type; AIS, wind data, current data, water tem-
perature and depth data. These data have only one input port.
3.5.9 [NET WORK SETTINGS] menu
Open the main menu then select [RADAR INSTALLA-
TION]o [NEXT]o [NETWORK SETTINGS] to open
the [NETWORK SETTINGS] menu.
Note 1: Network settings should be done while the ra-
dar is disconnected from the LAN network, as a stand-
alone radar.
Note 2: The system restarts automatically after the
network settings are changed.
Note 3: When you change the radar number, this
equipment restarts automatically. After restarting, con-
firm the IP address in [NETWORK SETTINGS].
[LAN1•3 IP ADDRESS]
For multiple radar systems using the network hub, the IP address is assigned accord-
ing to the radar No (See "[RADAR No.]" on page 3-11). Set the IP address as shown
in the following table. For C-type and A/B-type radars with Radar Plotter functionality,
a dedicated IP address is assigned.
Also, select the network type, CLASS C or B. When FAR-2xx8 radar is connected to
FEA-2xx7 series (ECDIS), set CLASS B.
Note: Do not set an IP address other than the address that corresponds to your radar
number and class in the following table.
For AIS For wind data For current data
For water temperature For depth data