4. INPUT/OUTPUT DATA
4-2
Output
**: These sentences are output in order of targets close to the own ship. The output
sentence and mode can be set at the [TT PRESET] menu (See section 3.5.5). The
baudrate can be set at the [BAUD RATE] menu (See section 3.5.6).
IEC 61162 input sentence and priority
Data Specification Contents Remarks
Radar system
data
IEC 61162-1,
RS-232C,
IEC 61162-450
RSD, OSD, TLL For ECDIS, PC plotter
TT data** IEC 61162-1,
IEC 61162-450
TTD, TTM, TLB For ECDIS
Alert handling
signal
IEC 61162-1,
IEC 61924-2,
IEC 61162-450
ALR, ALF, ALC,
ARC, HBT,
EVE
For BAMS
ALR and ALF are switched by
menu setting.
Sub monitor
signal
HD, BP Trig-
ger, Video
1 port for radar
2 ports for ECDIS
External LCD
monitor signal
DVI Same as main
display unit
2 systems in total
VDR R, G, B, H, V,
IEC 61162-450
Same as main
display unit
1 port
Alert signal Contact closure Output to alarm
system by using
photo-relay
4 systems, Output contents are
selected by menu.
Contents Sentence and priority
Heading (True)*1
THS>HDT*
1
*
2
>VHW*
4
>HDG*
5
Heading (Magnetic)*
5
HDG*
5
>HDM*
5
>VHW*
4
Magnetic deviation*
5
HDG*
5
>RMC
AIS target message, alert VDM, VDO, VSD, ABK, ALR
Date, Time ZDA
Position*
3
GNS>GGA>RMC>GLL
or GLL>GNS>GGA>RMC
Datum DTM
Course over the ground VTG>RMC
Speed over the ground (SOG)(GPS) VTG>RMC
Speed over the ground (LOG (BT)) VBW
Speed through the water (STW) VBW>VHW
Alert handling ACK, ACN, HBT
Waypoint RMB>BWR>BWC
Route WPL, RTE
Wind Speed and angle
(Theoretical, True)
MWV>VWT*
2
Wind Speed and angle (relative)
MWV>VWR*
2
Depth
DPT >DBT>DBS*
2
>DBK*
2
Water Temperature MTW
Current VDR, CUR
Rate of turn ROT
Monitor Setting DDC, RAQ