2. WIRING
2-2
2.1.1 Standard wiring
A Cat 5e LAN cable (RW-00135, RW-00339) connects between the Antenna Unit
(Power Supply Unit for FAR-2x58) and the Processor Unit. The maximum length of the
cabling between the Processor Unit and the Antenna Unit is 80 m.
Retrofit (using antenna cable RW-9600/4896) or foremast installation is also possible,
with the installation of a pair of LAN Signal Converters, one in the Antenna Unit, the
other in the Processor Unit. See section 2.10.
X-band/S-band (TR-UP) radars for FAR2x18/2x28/2x38 radars
The appropriate radars are FAR-22x8(-BB), FAR-2228-NXT(-BB), FAR-23x8, FAR-
2328-NXT, FAR-22x8S(-BB), FAR-23x8S(-NXT) and FAR-2238S-NXT(-BB).
DVI-D/D SINGLE LINK
5/10 m
DTI-C5E 350 VCV
10/20/30 m
DVI-BNCX5+GND-L2.0
2 m
FR-FTPC-CY
10/20/30 m
100-230 VAC
1ø, 50-60 Hz
100-230 VAC
100-230 VAC
Transformer
440 VAC
1ø, 50-60 Hz
Switching
HUB
HUB-100
Control Unit
RCU-016
Monitor Unit
MU-190 or
MU-231 or
MU-270W
VDR
(IEC61162-450 format)
VDR
(Analog RGB)
Intelligent Hub
HUB-3000
Gyrocompass
(AD-10 format)
Gyrocompass
(IEC61162 format)
AIS Transponder
EPFS (GPS)
Sub display
Antenna Cable (LAN+serial)
RW-00135
15/30/40/50 m
100-115/220-230 VAC
1ø, 50-60 Hz
(for de-icer)
PROCESSOR
UNIT
RPU-025
ANTENNA
UNIT
Control Unit
RCU-014 or
RCU-015 or
RCU-031
XH10P-W-6P
2.3/10/20/30 m
XH10P-W-5P
TTYCSLA-4
TTYCSLA-4
AMS
(IEC61162 format)
TTYCSLA-4
AMS
(Contact)
Sub Monitor 1
of ECDIS
TTYCSLA-7
RW-4864
1/5/10/15 m
Sub Monitor 2
of ECDIS
RW-4864
1/5/10/15 m
ECDIS
TTYCSLA-4
TTYCSLA-1Q
SDME (Speed log)
TTYCSLA-1Q
TTYCSLA-1Q
100-230 VAC
DPYC-1.5
DPYC-1.5
DPYC-1.5
DPYC-2.5
24 VDC
Rectifier
PR-850A
100/110/120 VAC
1ø, 50-60 Hz
DPYC-1.5
DPYC-6
S03-92-* (8P)
15/30/40/50 m
DPYCY-1.5
:
Standard supply
:
Optional or local supply
1.5/10/20/30 m
USB Device
max. 2 m
(For chart update)
USB Device
max. 5 m
(For mouse)
For AC
power
For DC
power
or