2. WIRING
2-6
WAGO connector
A terminal opener is provided on the circuit board as below.
• FAR-2x18/2x28/2x38 radars
• FAR-2x58 radars
RW-00135 (Antenna cable for FAR-2x18/2x28/2x38 radars)
For X-band radar, the end of the antenna cable RW-00135 which connects to the An-
tenna Unit is pre-fabricated.
Procedure
1. Twist the cores.
2. Press the terminal opener
downward.
3. Insert the wire to hole.
4. Remove the terminal
opener.
5. Pull the wire to confirm
that it is secure.
Press downward.
WAGO
connector
Terminal
opener
TB Board 03P9648
(Processor Unit)
RF-TB Board 03P9570
(Antenna Unit/Transceiver Unit)
Terminal Opener
Terminal Opener
(Power Supply Unit)
RF-TB Board 03P9665
(Antenna Unit)
Terminal Opener
Terminal Opener
Shield case