2. WIRING
2-50
5. Connect the connectors to the TB Board. referring to the interconnection diagram.
6. Connect the ground wires of cables to the near ground terminals on the plates.
Connection of cables for Control Unit
1. Unfasten the four bolts, indicated with dashed circles below, to remove the upper
plate of the cable clamp.
2. Remove the appropriate spacer to pass the cable for control unit on the lower
plate. The recommended cable entrance is shown as below.
3. Fasten the cable to the post part of the plate
with a cable tie (local supply).
Note: Be sure the vinyl sheath on the post.
J620
(AD-10, GYRO)
J618 (AMS serial) J615 (AIS)
J621
(RS-232C for brill control)
J611
(Control Unit)
J619 (ECDIS)
J613 (AMS contact)
J608 (Antennna)
J503
Connect LAN cable
for antenna cable.
J510/J511
Connect cable for sub
monitors of ECDIS.
J617
(LOG)
J616
(GPS)
J614
(HDG)
Lower
plate
Control Unit
Control unit cable
Lower plate