EasyManua.ls Logo

Furuno FCV-1100L - Appendix 1 Transducer 50 Bl-12;50 Bl-24 H

Furuno FCV-1100L
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AP-1
APPENDIX 1
TRANSDUCER 50BL-12/50BL-24H
When using the transducer 50BL-12/50BL-24H, see this appendix.
Transducer, thru-hull pipe and tank list
Frequency
(kHz)
Transducer
Hull
Material
Tank
(Code No.)
Fasten inside
hull (Code No.)
Fasten outside
hull (Code No.)
Steel
T-693
(000-015-044)
TWB-6000
(000-015-207)
TFB-7000
(000-015-209)
50/200 50BL-12/200B-8B
FRP
T-693F
(000-015-241)
TWB-1100
(000-015-218)
-
Steel
T-696
(000-015-048)
TWB-6000
(000-015-207)
TFB-7000
(000-015-209)
28/50 28F-24H/50BL-24H
FRP
T-696F
(000-015-244)
TRB-1100
(000-015-218)
-
Steel
T-697
(000-015-239)
TWB-6000
(000-015-207)
TFB-7000
(000-015-209)
50/88 50BL-24H/88F-126H
FRP
T-697F
(000-015-245)
TRB-1100
(000-015-218)
-
Steel
T-695
(000-015-047)
TWB-6000
(000-015-207)
TFB-7000
(000-015-209)
50/200 50BL-24H/200B-12H
FRP
T-695F
(000-015-243)
TRB-1100
(000-015-218)
-
Settings
1. Referring page 3-6, set the menu as below.
XDCR SELECT: MANUAL
FREQ: 50 kHz
2. At the terminal board at the rear of the display unit, fasten the crimp-on lug to C position.
(See page 3-5.)
Frequency Output (kW) Transducer Terminal
2 50BL-12 C
50
3 50BL-24H C

Other manuals for Furuno FCV-1100L