1.2 Processor Unit
There are two types of Processor Units: CV-1203 (FCV-1200L) and CV-1203M (FCV-1203LM).
With the EXIF Board Assy. (standard on FCV-1200LM, optional on FCV-1200L) external
equipment such as an echosounder interface, switch box, etc. can be connected.
The unit can be mounted on the deck, a desktop or on a bulkhead. Select a mounting location
considering the points below.
Locate the unit out of direct sunlight.
Select a location where temperature and humidity are moderate and stable.
Consider the length of the cable connected between the processor unit and monitor and/or
interface unit.
Locate the unit where its cover can be easily removed and cabling easily accessed.
For mounting on a bulkhead be sure the mounting location is strong enough to support the
unit under the pitching and rolling normally encountered on the vessel.
Leave sufficient space around the unit for maintenance and servicing. Recommended
maintenance space appears in the outline drawing at the back of this manual.
Tabletop or deck mounting: Fasten with four self-tapping screws.
Bulkhead mounting: Screw in four self-tapping screws in mounting location, leaving 5 mm
protruding. Set the processor unit to the screws and tighten screws.