2-7
Use a monitor cable (max. length 15 m) to connect a commercial monitor. A D-sub 15P
connector with three rows of pins is required for connection at the interface unit. The monitor
must satisfy the following requirements:
VGA type
Analog RGB, 0.7Vpp, positive polarity
TTL level H, V, negative polarity
Note 1:
Two interface units may be connected.
Note 2:
When connecting the Monitor Unit MC-101C or an interface unit to the terminal
DATA/VIDEO OUT its connector will touch the connector of DATA/VIDEO IN. To prevent this, cut
and remove the rubber covers and fixing metals from the connectors as below to attach them to
the interface unit.
Cut and
remove
covers.
Remove
fixing metals.
Connectors touch here.
Figure 2-9 Remover fixing metals and covers from connectors
of DATA/VIDEO IN and DATA/VIDEO OUT
Note 3:
When connecting the interface unit to the Monitor Unit MU-101C or connecting two
interface units in parallel, cable lengths should be as below. Further, two cables (type 06S4078)
of 10 m in length cannot be used.