3-3
3. Press [ ] to select MONITOR TYPE, and then press [+] to open the dialog box.
PORTRAIT LANDSCAPE
4. Use [+] or [-] to select appropriate monitor type, and then press [+] to close the dialog box.
5. Turn off the power to change picture orientation.
3.3 Transducer Data (FCV-1200L only)
This paragraph provides information necessary for entering transducer data. You enter
transducer data by either transducer model number (for FURUNO transducer, page 3-4) or
specification (page 3-5). The FCV-1200L is programmed for use with the following
non-FURUNO transducers.
Maker Frequency Transducer Type Remarks
Simrad 38kHz 38E-9-18S1(2kW)
Airmar 38kHz 38E-M42(3kW)
28kHz 28/55/100(3kW)
33kHz 36/65/110(3kW)
36kHz 32/40(3kW)
41kHz 40/75(3kW)
50/200/400(2kW) 50kHz
50/3K/3F(3kW)
55kHz 28/55/100(3kW)
60kHz 36/65/110(3kW)
67kHz 40/75(3kW)
100kHz 28/55/100(3kW)
118kHz 36/65/110(3kW)
200kHz 50/200/400(2kW)
Honda
400kHz 50/200/400(2kW)
50kHz TGM50/200 Suzuki
200kHz TGM50/200
Same as FURUNO 50/200-1T(1kW)
Set the transducer model number
properly.
Wrong transducer setting can damage the
transducer and void the warranty.
CAUTION
Do not enter transducer data by speci-
fications if model number of transducer
used is programmed in the equipment.
Wrong transducer setting can damage the
transducer and void the warranty.
CAUTION