iv
SYSTEM CONFIGURATIONS
The ECDIS EC1000 Workstation displays electronic seachart and operates as user
interface for the system. The ECDIS processor is connected to various sensors, and
performs navigation calculations and route monitoring. Connections to interfaces are
typically made with a LAN (Local Area Network) Adapter. The ECDIS processor can be
used for both route planning and route monitoring. If required, there can be additional
identical ECDIS EC1000C Workstation(s) connected to the same LAN to share the tasks of
the ECDIS. If the system incorporates more than one ECDIS EC1000C Workstation, one or
more workstation(s) can be used as a user interface (with “full” usage rights) and one or
more workstation(s) may be used as planning stations (usage rights as “planning”). If the
system has two or more Workstations connected together as multi-workstations, the system
keeps data on the workstations harmonised and also tracks selections and settings made
on any workstation.
Typically there can be the following kinds of workstation configuration:
Mode as Single, only one workstation is used in the system.
Mode as Multi, two or more workstations are used in the system where usage rights and
sensor source of workstations can be changed by the user.
For more information, see the operator’s manual.
One workstation
ECDIS Monitor
Conning Monitor
ECDIS PROCESSOR
EC1000C
Control Unit
RCU-018
or
TB Control Unit
RCU-015FEA
L
AN ADAPT
ER
EC-1010
LAN ADAPTER
EC-1010
B ADAPTER
EC-1020
ARPA RADARS
POSITION-FIXING EQUIPMENT
TRACK PILOT
LOG/DUAL AXIS LOG
AIS
GYRO COMPASS
POSITION-FIXING EQUIPMENT
ENGINE CONTROL
E
CHOSOUNDE
R
WIND SENSOR
WATER TEMP. METER
AMWSS (Alarm Monitoring
Watch Safety System)
GYRO COMPASS
(SYNCHRO, STEPPER)
LOG (200P/NM)
ANALOG INPUT (8 CHANNEL
S)
ALARM OUTPUT (8 CHANNEL)
100-230 VAC
100-230 VAC
100-230 VAC
CALCOMP
DRAWING-
BOARD III
DIGITIZER
PRINTER
OPTION
EXTERNAL
DEVICE
RADAR 1 (VIDEO, HL, AZ)
HUB-
100
100-230 VAC
24 VDC
RADAR OVERLAY PCB
RADAR
SWITCH
DAR 2
(VIDEO, HL
, AZ)
Remote Control Unit
RCU-016
(WORKSTATION)
Rectifier
PR-62
100/230 VAC
(USB)
ALARM OUTPUT
(ECDIS SYSTEM FAIL)
RA
FAR-2xx7 series
DVI or RGB
DVI or RGB
24 VDC
Rectifier
PR-62
100/230 VAC
24 VDC
Rectifier
PR-62
100/230 VAC
MU-201CE (FEA-2107)
MU-190 (FEA-2107-D)
MU-231CE (FEA-2807)
MU-231 (FEA-2807-D)
MU-201CE (FEA-2107)
MU-190 (FEA-2107-D)
MU-231CE (FEA-2807)
MU-231 (FEA-2807-D)